Kioxia GP2 adds a flash tier for direct GPU reads in AI servers
Kioxia's GP2 announcement targets 512-byte reads and larger datasets. Benchmark conditions and the evaluation schedule will determine where the added flash tier is useful.
The Tokyo announcement and sample schedule
Kioxia announced the GP2 series in Japan on November 26. It follows the GP1 revealed in August and combines third generation XL-FLASH with a PCIe 6.0 x4 interface and NVMe 2.3 support. Kioxia reports more than 18 million random reads per second at 512 bytes in its own testing. It expects up to 28 gigabytes per second for sequential reads, a figure based on development hardware and the interface bandwidth. The company plans functional evaluation samples for selected customers by the end of 2027. That schedule establishes a pilot window. General availability and final production specifications remain open.
An additional tier alongside HBM
High bandwidth memory provides a GPU with fast working space for frequently used data. Large graph workloads can exceed that capacity, leaving the system to fetch some node features from another tier. GP2 is designed for GPU access to a flash tier. A practical deployment could keep hot data in HBM and bring in less frequently used records as needed. The gains would depend on access patterns and the amount of concurrency the application can sustain. A useful evaluation therefore has to include data placement and cache policy, alongside the drive and its interface.
What eighteen million reads measures
IOPS counts input and output operations completed per second. At exactly 512 bytes per request, 18 million reads imply about 9.216 gigabytes of payload each second before accounting for protocol overhead. The separately stated 28 GB/s figure describes expected sequential reading. Each figure applies to a different workload. Small requests can make command handling and latency dominant, while large contiguous transfers can make the link bandwidth the limiting factor. Kioxia's comparison against GP1 also uses the 512-byte read test. A buyer would need the queue depth, block size distribution and tail latency on representative servers to judge its value.
A representative pilot for graph workloads
Graph neural networks can fetch many small records as they follow relationships across a data set. Some similarity-search workloads also jump among disparate data fragments. Start by recording time spent waiting for input on an existing server, together with the observed distribution of read sizes. Compare the existing data path with a flash tier using the same model, batch size, warmed cache policy and request trace. Measure end-to-end latency, accelerator utilisation and system power together. These measurements make it possible to distinguish an improvement in drive-level reads from an improvement in completed application work.
Evidence needed before committing to production
An evaluation system should establish whether its operating system, drivers, GPU libraries and storage stack support the planned direct reads. Operators can then test how a failed drive is handled, how requests share capacity across GPUs and how sustained traffic affects temperature. Drive endurance has different implications for a largely read-only cache and a tier rewritten throughout the day. StorageReview singles out the development of a GPU-to-NVMe software path for small reads. An adoption decision will need final hardware specifications and a comparison against the cost, energy use and latency of an alternative HBM or DRAM expansion.
Archive photo User5515 / Wikimedia Commons · Kioxia BG6 ↗ · CC0 · Cover cropped
Sources and verification
- Primary sourceKioxia Corporation ↗
- Reporting / cross-checkServeTheHome ↗
- Reporting / cross-checkStorageReview ↗
Reader discussion
Where is human oversight essential for this technology?
No comments yet. Be the first to contribute.
Write a comment